Junsi China
Home   |   About us   |  News   |  Products  |  Download   |  Contact  |  中文 
  Products List
   
  Object List
   
  Link websites
 
 
  
CODE:
CellLog8S
NAME:
Cell Voltage Monitor & Logger
CLASS:
Cell Volt Monitor / Logger
 
    CONTENT

Specifications                                                                            

Lithium (LiPo/LiIo/LiFe) battery cell count

2 – 8 series

Pack voltage range

4.0 – 43.0VDC
(USB can provide lower voltage 1.0V)

Alarm pack voltage range

0.1 – 4.3VDC

Cell voltage range

1.3 – 4.9VDC

Alarm cell voltage range

1.3 – 4.9VDC

Voltage display resolution

1mV

Current loading of test

8mA

Maximum voltage for alarm port

50VDC

Current drain for alarm port

<500mA

Log Files storage

16Mbit (36 hours)

Sample logging time interval

2 seconds

PC Connect

USB port

Weight

18g

Dimensions (L *W * D)

62X39X12mm   
2.44”X1.53”X0.47””

External controls and connections                                          

 

Special features                                                                          

  • Small size with multiple functions, backlight 128*64 lattices LCD and Buzzer Tone Reminder; the interface can be operated smoothly.
  • CellLog 8S can not only measure 2-8S Li battery individual voltage, but also measure NiMH, NiCd, Pb battery pack voltage.
  • It can be set Individual Voltage Alarm and Pack Voltage Alarm, Overvoltage Alarm, Low Voltage Alarm, Differential Voltage Alarm and Time Over Alarm. What’s more, the extra alarm output can be linkage controlled by the users.
  • It has 8 sets default monitor alarm settings, which can be selected for different battery packs.
  • CellLog 8S has been 100% calibrated before it enters to the market, at the same time, it supports the calibration by users themselves.
  • CellLog 8S has a 16Mbit flash storage, which can log offline data in 36 hours.
  • Support upgrading the hardware program by USB port. The CellLog 8S also supports the “logview” software and can display, plot and analyze the charge and discharge data by it. (See detail information about logview in the following website: http://www.logview.info)

User's Manual

 

 
      TIME:2010-9-9 
 
 
Copyright © 2005 -2007 Junsi All Rights Reserved